Industrial Inspection & Measurement Instruments

Coating Thickness Gauges

DR6000A

DONGRU DR6000A Protective Coating Thickness Gauge

For thick protective and anti-corrosion coatings on suitable metal structures.

Request technical guidance

Capabilities / DR6000A

What the product record supports.

Four confirmed points: material, measurement, readout and power. Full values are in the specification table below.

Compatible substrates

Ferrous metal

Measurement

magnetic · 0-6000μm · ±3%H+2μm

Readout

0.1μm/1μm/0.01mm · 2.8-inch color display

Power & body

3.7V lithium battery(2000mAH) · 141×69×27mm / 242g

In practice

Where the DR6000A is used

Measure thick protective and anti-corrosion coatings on steel structures and pipework, up to a 6000 μm build. One magnetic range covers the whole system instead of stacking readings across gauges.

DR6000A protective coating thickness gauge with magnetic probe

01

Thick anti-corrosion systems

0–6000 μm

Read heavy protective coatings — epoxy, polyurethane and similar systems — up to 6 mm in a single measurement.

Ferrous steel only — not for aluminium or other non-ferrous substrates.

02

Pipework and steel structures

Magnetic induction

Walk a pipeline or structure and record the coating build section by section, with a Φ16 mm contact area.

Minimum substrate thickness 0.4 mm.

03

Site-ready power

3.7 V 2000 mAh

6000

μm · measuring range

A 2.8-inch colour screen and a rechargeable 2000 mAh cell keep the gauge running through site inspection rounds.

Stated accuracy is ±3% of H + 2 μm; at curved parts the radius must be at least 5 mm convex or 25 mm concave.

Magnetic induction · 0–6000 μm · 2.8-inch colour LCDDR6000A · Protective coating thickness gauge

Where it stopsFerrous metal substrates only. Not for non-ferrous metals, and not for coatings on plastic or concrete.

Model / DR6000A

Technical specifications

Values come from one shared product record; confirm suitability for your measurement task.

0-6000μm

Measuring range

Confirm your material, measuring method and application before selecting an instrument.

Measurement

Measurement method
magnetic
Measuring range
0-6000μm
Compatible substrates
Ferrous metal
Accuracy
±3%H+2μm
Resolution
0.1μm/1μm/0.01mm
Minimum substrate thickness
0.4mm
Minimum measurement area
Φ16mm
Minimum curvature
convex 5mm;concave 25mm

Instrument & environment

Model
DR6000A
Product code
DR-CT-DR6000A
Display
2.8-inch color display
Power supply
3.7V lithium battery(2000mAH)
Dimensions / weight
141×69×27mm / 242g
Operating environment
0℃-60℃, 20%-90%RH

DR6000A

Discuss this model

Tell us your material, expected range and site conditions. We can help check the instrument and probe fit.